Model SCH-30A-H SCH-40A-H
Solar System Voltage 12V/24V/36V/48V Auto work
Electrical
PV Operating Voltage 18~150Vdc@12V 35~150Vdc@24V  50~150Vdc@36V  60~150Vdc@48V
Max. PV input power 12V 400W 12V  600W
24V 800W 24V 1200W
36V 1300W 36V 1700W
48V 1700W 48V 2300W
Rated input current 30A 40A
Rated DC load current 40A
Self consumption 2W
Max.Conversion Efficiency 97.5%
Protection PV array short circuit, over charging,battery reverse polarity,output short circuit
Battery charging
Battery Type Sealed  Gel AGM  Flooded  Lithium Battery
Charge algorithm 4 stage: Bulk, Absorption, Float, Equalize charging
Bulk charge voltage Sealed: 14.4V AGM 14.2V  Gel:14.2V Flooded:14.6V User defined:10-15V
Float charge voltage Sealed/Gel/AGM:13.8V  Flooded:13.7V User defined:10-15V
Equalize charge voltage Sealed 14.6V  AGM:14.8V Flooded:14.9V
Load disconnect voltage 10.5V ~12V Adjustable
Low voltage reconnect voltage 12.5V
Temperature compensation 5MV/℃/2V with BTS
Communication
Communication Port RS485(Standard) Ethernet RS232 Optional with On line monitoring system
Physical
Net weight 3.3kg
Gross weight 3.7kg
Dimension 350*280*180MM
Cooling Heatsink cooling
Enclosure IP54
Environment
Ambient operating temperature -25℃~60℃
Storage Temperature -40℃~80℃
Humidity 100% non-condensing
Warranty One years