• High frequency and double conversion online technology
  • Fully digitized microprocessor control
  • Wide input voltage range
  • LCD display
  • UPS startarrow up without battery (for 1-3KVA)
  • Cold startarrow
  • Advanced battery management
  • Automatic battery charging in UPS off mode
  • Lightning and surge protection
  • Short circuit and overload protection
  • Fan speed auto control when loads varies
  • Network/fax/modem surge protection (for 1-3KVA)
  • Optional extension battery pack
  • Battery voltage display
  • Load capacity display
  • EMI/RFI noise filter
  • Smart RS232 communication with monitoring software
  • Optional SNMP card slotarrow
  • EPO function (optional)
  • Input L and N reversed alarm function (for 1-3KVA)
  • Parallel capacity (for 6-10KVA)
  • Model: BGK 10.0HFi
  • Capacity: 10KVA/7KW
  • Voltage Range: 176±5VAC – 276±5VAC
  • Frequency Range: 46 – 54Hz±0.5Hz or 56 – 64Hz±0.5Hz auto sensing
  • Phase: Single phase
  • Power Factor: ≥0.98
  • Voltage Range: 220Vac±1%
  • Phase: Single Phase
  • Frequency Range: Synchronise with the utility on AC mode; 50Hz/60Hz±0.2% on battery mode
  • THD(linear load): <3%
  • THD(non-linear load): <6%
  • Load capability: >110%, 30s turn to bypass mode; >150%, 300ms turn to bypass mode
  • Crest Factor: 3:01
  • Short circuit protection: 5 cycles turn off inverter, no transfer to bypass, provide alarm (AC mode). 5 cycles turn off inverter, provide alarm(battery mode). Input fuse blown or breaker action(bypass)
  • Waveform: Pure sine wave
  • Transfer Time: 0ms (Between AC mode and Battery mode)
  • Transfer Time: 0ms (Between AC mode and Bypass mode)
  • Efficiency: ≥88%
  • Model: 12V sealed VRLA maintenance freearrow
  • DC Voltage: 240VDC
  • battery: 20x12V/7AH
  • Back up time(half load): 13min
  • Back up time(full load): 5min
  • Charge current(standard unit): 1A
  • Charge current(long time unit): 5A
  • Recharge time:90% capacity after 8hrs charging
  • Communication Interface: RS232; SNMP (optional)
  • Parallel Port: parallel availability for redundancy and load sharing up to three units
  • LCD Indicator: 1. input voltage/frequency, battery voltage, output voltage/frequency, load watt/VA and percent, inverter temperature. 2.Operation mode such as “on line”, “on batt”, or ” or bypass”
  • LED Indicator: 1. Green LED for normal operation, 2. Yellow LED for warning condition, 3.Red LED for abnormal operation
  • Noise Level: <55dB
  • Temperature: 0⁰C – 40⁰C
  • Humidity: 0% – 95%(non-condensing)
  • Altitude: <1500m
  • Storage temperature: −40⁰C – 50⁰C
  • Standard unit Net/Gross weight (kg): 92/107
  • Long time unit Net/Gross weight (kg): 36/51
  • Dimension (W*D*H)mm: 270x570x720
  • Packing Dimension (W*D*H)mm: 370x670x940