Input | |
Voltage | 400 Vac |
Tolerance | 320 – 450V |
Frequency | 50Hz ± 6% |
Output | |
Voltage | 400Vac ± 1% |
Power Factor | 0.8 |
Transfer Time | 0 ms |
Frequency | 50Hz ± 6% (On Mains) |
50Hz ± 0.5% (On Battery) | |
Waveform | Pure Sine Wave |
THDi | Linear Load ≤ 3%; Non-linear Load ≤ 5% |
Crest Factor | 3 : 1 (Max) |
Bypass Facility | Maintenance Bypass and Static Bypass |
DC Bus / DC Functions: | |
DC Bus Voltage | 384V |
Charging Current | 5 – 20A, Adjustable |
Cold-Start Function | Yes |
Battery Charging in OFF Mode | Yes |
Battery Type | Sealed, Maintenance-free VRLA |
LCD User Interface: | |
Metering / Indications for | Voltage |
Load % | |
Frequency | |
General Status | |
Alarm | |
Communication: | |
Interfaces | RS232 |
Overload | |
105~125% | 10 mins (Output swithes to bypass after 60s) |
>130% | 1 min |
Environment: | |
Temperature | 0 ~ 40oC |
Humidity | 20 ~ 90% Non-condensing |
Altitude | < 1000m |
IP Class | 20 |
Physical: | |
Dimensions (mm) | 10-20kVA : 560 x 700 x 1040 (W x D x H) |
30-40kVA : 660 x 800 x 1380 (W x D x H) | |
60-80kVA : 1540 x 880 x 1570 (W x D x H) | |
100-200kVA : 2000 x 980 x 1800 (W x D x H) | |
Weight (Kg) | 10kVA : 260kg |
15kVA : 350kg | |
20kVA : 400kg | |
30kVA : 480kg | |
40kVA : 650kg | |
60kVA : 650kg | |
80kVA : 1200kg | |
100kVA : 1330kg | |
120-200kVA : On Request |
100kVA Vectronic Online UPS
₦6,900,000 ₦7,200,000
Description:
Profie: Tower
Range: 100kVA
Voltage: 400Vac
Frequency: 50Hz
Related products
-
UPS
APC Smart UPS 1500VA USB & Serial RM 2U 230V
0 out of 5(0)Protects connected loads from surges, spikes, lightning, and other power disturbances. Automatically starts up the connected equipment upon the return of utility power. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
SKU: n/a
Recently Viewed products
SMK 63A SINGLE POLE AC BREAKER 230/400V
A range of 10x38mm fuse links specifically designed for protecting photovoltaic strings. These fuse links are capable of interrupting low overcurrents associated with faulted photovoltaic string arrays
(reverse current, multi-array fault)
Structural Characteristics
□ According to IEC60269-1
□ Rated current: 1-32A
□ Rated voltage: DC 1000V
□ Rated breaking capacity:DC 33kA
□ Operating class gPV for Solar protection
Specification
Pole 1P
Rated Voltage Ue (V DC) 1000
Rated Current In (A) 1, 2, 3, 4, 5, 6, 8, 10, 12,15, 20, 25, 32
Biggest Block Ability(KA) 33
The Most High Power Consumption(W) 3.5
30W All in one solar street light
30w All In One Solar Street Light Outdoor For Smart City Public Lighting
300W Pure Sine Wave Inverter
Hybrid inverter SCI Series is equipped with MPPT solar charge controller to maximize and regulate DC power from the solar array for charging the battery bank. The transformer-based design provides reliable power conversion in a compact size. Besides, it’s worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors, and laser printers as well as electronic loads like TVs, Computers, power tools,s and battery chargers.