Zektron online UPS TS-11 series adopts online double conversion design and digital control technology and it features high input and output power factor (0.9). With ECO mode for energy-saving, intelligent battery management and excellent network management, it is a cost-effective power solution for your critical devices. When UPS is on battery mode, it can shut down unnecessary load and extend the backup time of the critical load.
80kVA Vectronic Online UPS
₦5,800,000 ₦6,700,000
Description:
Profie: Tower
Range: 80kVA
Voltage: 400Vac
Frequency: 50Hz
Related products
-
UPS
BLUE GATE 1530KVA UPS BG 1530 Elite Pro
0 out of 5(0)The Blue Gate Offline UPS BG1530 is efficient, durable, and boasts of three LED indications that make it easy for you to understand as well as a digitized microprocessor control that stabilizes the flow of power and overload protection that makes it not affect any of your household appliances. The energy-saving function comes in a green and red color mode that lets you know when the UPS battery is full and when it is also getting low to enable you to switch off your appliances before it finally shut off. The Blue Gate Offline UPS provides an alternative power supply to connects with any electronic equipment when the primary power source is not available. You could make use of the UPS for your electrical equipment with generators that are compatible with the voltage of the UPS to enjoy your television, freezers, air conditioners, and more without fluctuation of supply of power. The UPS charges manually and automatically as you are making use of it when there is stable light or with a generator and is helpful in protecting our appliances from damages and have prevented serious hardware damage and data loss when working seriously and focusing on your work without minding the blackout of power supply or fluctuations
SKU: n/a -
UPS
APC Smart UPS 1500VA USB & Serial RM 2U 230V
0 out of 5(0)Protects connected loads from surges, spikes, lightning, and other power disturbances. Automatically starts up the connected equipment upon the return of utility power. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
SKU: n/a
Recently Viewed products
APC Back-UPS 700VA – BX700UI
APC Back-UPS 700VA, 230V, AVR, IEC Sockets
Automatic Voltage Regulation (AVR)Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.Telephone dataline surge protectionProvides protection of connected equipment from power surges traveling on telephone lines.USB connectionUse your PC to access additional power protection and management features for your UPS via a USB Port.
GENUS 2.5KVA/36V INVERTER
Kartel 2.5kWH/12V Lithium Battery
Kartel Battery
The Kartel Valve Regulated Lead Acid batteries has been developed as advanced series, to provide reliable performance in Solar PV Systems, Uninterruptible Power Supply, Telecom, Information Technology and Emergency Power Supply Systems.
HYBRID INVERTER 4KVA/48V/60A
Hybrid Inverter
4KVA
The Hybrid Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
BLUEGATE 24Ah 12V UPS Replacement Battery
True double-conversion design with high adaptability to harsh mains conditions
• DSP design enables precise and reliable control
• High efficiency results in energy saving
• Output power factor 0.8 (up to 0.9 under 30℃)
• Wide AC input range (110-300VAC)
• Automatic switching between 50/60Hz system
• Automatic boost/buck
• ± 1 % voltage regulation
• Supports AC generator
• Supports DC start-up and auto restart
• Supports USB/SNMP/RS485/AS400 communication card
Input | |
Voltage | 400 Vac |
Tolerance | 320 – 450V |
Frequency | 50Hz ± 6% |
Output | |
Voltage | 400Vac ± 1% |
Power Factor | 0.8 |
Transfer Time | 0 ms |
Frequency | 50Hz ± 6% (On Mains) |
50Hz ± 0.5% (On Battery) | |
Waveform | Pure Sine Wave |
THDi | Linear Load ≤ 3%; Non-linear Load ≤ 5% |
Crest Factor | 3 : 1 (Max) |
Bypass Facility | Maintenance Bypass and Static Bypass |
DC Bus / DC Functions: | |
DC Bus Voltage | 384V |
Charging Current | 5 – 20A, Adjustable |
Cold-Start Function | Yes |
Battery Charging in OFF Mode | Yes |
Battery Type | Sealed, Maintenance-free VRLA |
LCD User Interface: | |
Metering / Indications for | Voltage |
Load % | |
Frequency | |
General Status | |
Alarm | |
Communication: | |
Interfaces | RS232 |
Overload | |
105~125% | 10 mins (Output swithes to bypass after 60s) |
>130% | 1 min |
Environment: | |
Temperature | 0 ~ 40oC |
Humidity | 20 ~ 90% Non-condensing |
Altitude | < 1000m |
IP Class | 20 |
Physical: | |
Dimensions (mm) | 10-20kVA : 560 x 700 x 1040 (W x D x H) |
30-40kVA : 660 x 800 x 1380 (W x D x H) | |
60-80kVA : 1540 x 880 x 1570 (W x D x H) | |
100-200kVA : 2000 x 980 x 1800 (W x D x H) | |
Weight (Kg) | 10kVA : 260kg |
15kVA : 350kg | |
20kVA : 400kg | |
30kVA : 480kg | |
40kVA : 650kg | |
60kVA : 650kg | |
80kVA : 1200kg | |
100kVA : 1330kg | |
120-200kVA : On Request |