Zektron online UPS TS-11 series adopts online double conversion design and digital control technology and it features high input and output power factor (0.9). With ECO mode for energy-saving, intelligent battery management and excellent network management, it is a cost-effective power solution for your critical devices. When UPS is on battery mode, it can shut down unnecessary load and extend the backup time of the critical load.
80kVA Vectronic Online UPS
₦5,800,000 ₦6,700,000
Description:
Profie: Tower
Range: 80kVA
Voltage: 400Vac
Frequency: 50Hz
Related products
-
UPS
Eaton 5E Series 1500VA UPS
0 out of 5(0)Eaton 5E 1500VA USB 230V GeneralTopologyLine Interactive with Automatic Voltage RegulationConfigurationTowerStyle Number5E1500iUSBPart Number5E1500iUSBRating (VA/Watts)1500VA/900WDimensions (H x W x D, mm)330 x 180 x 133Weight (kg)10.46Warranty2 years Electrical InputConnection(1) IEC-320-C14
Input Voltage Range170-280VNominal Voltage230 VOperating Frequency50/60Hz Electrical OutputNominal Voltage230VOutlets(6) IEC-320-C13
BatteryBattery ManagementPermanent battery recharge, cold start CommunicationsCommunication Ports1 USB portPower Management SoftwareEaton UPS Companion software Environmental & StandardsAudible Noise
Related
SKU: n/a -
UPS
APC Smart UPS 1500VA USB & Serial RM 2U 230V
0 out of 5(0)Protects connected loads from surges, spikes, lightning, and other power disturbances. Automatically starts up the connected equipment upon the return of utility power. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
SKU: n/a
Recently Viewed products
lithium ion battery 24v 200ah lifepo4 solar energy storage battery

lithium ion battery 24v 200ah lifepo4 solar energy storage battery
20kVA 96V 3 PHASE HDSX SERIES INVERTER
HDSX Inverter
15KVA – 50KVA
The HDSX series Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
20kVA 192V 3 PHASE HDSX SERIES INVERTER
HDSX Inverter
15KVA – 50KVA
The HDSX series Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
CHRISOLAR 10kw Pure Sine Wave 48v solar inverter
300W Pure Sine Wave Inverter
Hybrid inverter SCI Series is equipped with MPPT solar charge controller to maximize and regulate DC power from the solar array for charging the battery bank. The transformer-based design provides reliable power conversion in a compact size. Besides, it’s worry-free to start up motor-type loads such as refrigerators, motors, pumps, compressors, and laser printers as well as electronic loads like TVs, Computers, power tools,s and battery chargers.
BLUEGATE 24Ah 12V UPS Replacement Battery
True double-conversion design with high adaptability to harsh mains conditions
• DSP design enables precise and reliable control
• High efficiency results in energy saving
• Output power factor 0.8 (up to 0.9 under 30℃)
• Wide AC input range (110-300VAC)
• Automatic switching between 50/60Hz system
• Automatic boost/buck
• ± 1 % voltage regulation
• Supports AC generator
• Supports DC start-up and auto restart
• Supports USB/SNMP/RS485/AS400 communication card
Input | |
Voltage | 400 Vac |
Tolerance | 320 – 450V |
Frequency | 50Hz ± 6% |
Output | |
Voltage | 400Vac ± 1% |
Power Factor | 0.8 |
Transfer Time | 0 ms |
Frequency | 50Hz ± 6% (On Mains) |
50Hz ± 0.5% (On Battery) | |
Waveform | Pure Sine Wave |
THDi | Linear Load ≤ 3%; Non-linear Load ≤ 5% |
Crest Factor | 3 : 1 (Max) |
Bypass Facility | Maintenance Bypass and Static Bypass |
DC Bus / DC Functions: | |
DC Bus Voltage | 384V |
Charging Current | 5 – 20A, Adjustable |
Cold-Start Function | Yes |
Battery Charging in OFF Mode | Yes |
Battery Type | Sealed, Maintenance-free VRLA |
LCD User Interface: | |
Metering / Indications for | Voltage |
Load % | |
Frequency | |
General Status | |
Alarm | |
Communication: | |
Interfaces | RS232 |
Overload | |
105~125% | 10 mins (Output swithes to bypass after 60s) |
>130% | 1 min |
Environment: | |
Temperature | 0 ~ 40oC |
Humidity | 20 ~ 90% Non-condensing |
Altitude | < 1000m |
IP Class | 20 |
Physical: | |
Dimensions (mm) | 10-20kVA : 560 x 700 x 1040 (W x D x H) |
30-40kVA : 660 x 800 x 1380 (W x D x H) | |
60-80kVA : 1540 x 880 x 1570 (W x D x H) | |
100-200kVA : 2000 x 980 x 1800 (W x D x H) | |
Weight (Kg) | 10kVA : 260kg |
15kVA : 350kg | |
20kVA : 400kg | |
30kVA : 480kg | |
40kVA : 650kg | |
60kVA : 650kg | |
80kVA : 1200kg | |
100kVA : 1330kg | |
120-200kVA : On Request |