Product advantagePure Sine Wave, Strong loading ability for all kinds of equipment
Optional MPPT/PWM solar charge controller 60A
MPPT Efficiency max 98%
DC Start & Automatic Self-Diagnostic FunctionHigh Efficiency Design & ”Power Saving Mode” to Conserve Energy
Auto restart when Ac in recovering
Smart battery charger design for optimized battery performance
Selectable charging current based on applications
AC input/DC input/Solar input optional priority
Auto Restart Voltage
With energy-saving mode function, it is more convenient to use
Output short circuit protection function
Multiple parameters can be adjusted according to user needsProduct ParameterCapacity(VA)VC7000VAVC8000VAVC10000VARated Power5600W6400W8000WVoltage(DC)48VNominal Voltage220VACVoltage Range154-265VAC ;185-264VAC ( selectable)Frequency50-60HZ Auto sensingPower Factor0.8Voltage220VACFrequency50/60HZWaveformPure Sine WaveTransfer Time (AC to DC)<8msTransfer Time (DC to AC)<8msOutput Voltage Regulation土10%Bypass ModeYesSaver ModeYesEfficiency>98%Input ProtectionCircuit BreakerOutput ProtectionCircuit BreakerBattery TypeVRLA / GEL /GEL DEEP CYCLECharging Current40A45A55ALow Level disconnect (Selectable)40V -42VPWM controller Voltage range60VDC-150VDCPWM Maximum PV display open circuit voltage75VMaximum PV array power3400WMPPT control voltage range60V-150VMPPT Maximum PV display open circuit voltage150VDCMaximum solar charge current60ALCD indicator statusAC input voltage/input frequency, PV voltage, PV current , Output Voltage/Frequency, Battery voltage, Load current etc.LED indicator statusAC Line In:Green/Inverter:Red/Charging :Yellow/Alarm :RedLOW battery alarmAudible alarm-5 seconds beepingOverload alarmAudible alarm- continuous beepingFaultAudible alarm- continuous beepingTemperature0-60℃Humidity—10℃~90℃ Non condensingAccoustic Noise(db)>55dBSize L*W*H(mm)720mm*335mmm*210mmWeight (kg)273033
CHRISOLAR 10kw Pure Sine Wave 48v solar inverter
₦565,000
- For no city power areas, the battery pack can be charged by solar panels and used for night lighting;
- For the areas that city power is expensive, the battery pack can be charged during the electricity valley value
- period, and used at the peak power period.
- For the areas which power off from time to time, the battery pack can be used as UPS, to avoid information
- loss caused by sudden power outage.
- Battery pack is applicable to commercial lighting, industrial lighting, home lighting, outdoor lighting, camping
- tourism, farming, planting, the night market stalls, etc.
Related products
-
Inverter
Felicity Solar 3.5 KVA 48V INVERTER
0 out of 5(0)Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment.
SKU: n/a -
Inverter, Low Frequency Inverter
A&E 4KVA 24V PRO-Low Frequency Pure Sine Wave Inverter (TRANSFORMER BASE)
Inverter, Low Frequency InverterA&E 4KVA 24V PRO-Low Frequency Pure Sine Wave Inverter (TRANSFORMER BASE)
0 out of 5(0)LCD display , easy to read how inverter operates on LCD screen
Compatible to generator
5-levels DIP switch , offering customized performance
9-levels battery selector , Enable to charge Li-thium , Gel , lead-acid battery
DC(Solar)/AC prority optional
4 levels charge current adjustable
With RS232 communication port
With BTS & GTS , optimazing battery performance & start generator automatically
Power saver Switch , Enable to minimize standby consumption.SKU: n/a
Recently Viewed products
Eaton 5E Series 1500VA UPS
Eaton 5E 1500VA USB 230V GeneralTopologyLine Interactive with Automatic Voltage RegulationConfigurationTowerStyle Number5E1500iUSBPart Number5E1500iUSBRating (VA/Watts)1500VA/900WDimensions (H x W x D, mm)330 x 180 x 133Weight (kg)10.46Warranty2 years Electrical InputConnection(1) IEC-320-C14
Input Voltage Range170-280VNominal Voltage230 VOperating Frequency50/60Hz Electrical OutputNominal Voltage230VOutlets(6) IEC-320-C13
BatteryBattery ManagementPermanent battery recharge, cold start CommunicationsCommunication Ports1 USB portPower Management SoftwareEaton UPS Companion software Environmental & StandardsAudible Noise
Related
15kVA Relay stabilizer (45v-280v)
Description
Overview
Low, High, Fluctuating NEPA Voltage?
One Central Stabilizer for your entire Flat, Home, Office, etc.
Input Voltage Range of 45V-280V
Stablize and Protect all electrical appliances in your premises: Air Conditioners, Fridges, Freezers, TV, Home Theatre, DVD, Satellite Decoder, Electronics, Lights, Fans, Washing Machine, Microwave, Pumping Machine, Photocopier, Printer, Desktops, Notebooks, etc.
TM45-15K Relay Automatic Voltage Stabilizer Series is based on digital technology; provides voltage stabilization and protection to appliances and equipment; designed as a central stabilizer to handle all house loads.
Features
Applications
50kVA/360V 3 PHASE HDSX SERIES INVERTER
HDSX Inverter
15KVA – 50KVA
The HDSX series Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
HYBRID INVERTER 1.5KVA/24V/30A
Hybrid Inverter
1.5KVA
The Hybrid Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
Felicity Solar 750VA 12V Pure sine wave Inverter
Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment.