Input | |
Voltage: | 220 / 230 / 240 Vac |
Tolerance | Normal Over-voltage: 280V |
Withstand Over-voltage: 284V (max limit 285V) | |
Under-voltage limit: 145V (lowest limit 142V) | |
Output | |
Voltage: | 220/230V ± 10%, ± 1% on battery |
Power Factor | 0.6 . |
Transfer Time: | 2 – 6 ms (Typical) |
Frequency: | 50Hz (On Battery) |
Waveform: | Sine Wave on normal; Simulated Sine on battery |
DC Bus: | |
650VA | 12V |
1000VA | 24V |
1500VA | 24V |
2000VA | 24V |
3000VA | 48V |
Cold-Start Function: | Yes |
Charging Time: | 6hr to recover to 90% capacity |
Battery Charging in OFF Mode: | Yes |
User Interface: | |
Indications for | Normal mode |
Battery mode / mains fail | |
Low battery | |
UPS fault | |
Environment: | |
Temperature: | 0 ~ 40oC |
Humidity: | 20 ~ 90% Non-condensing |
Noise Level: | Noise Level: Less than 40dB |
Physical: | |
Dimensions | 600 – 650VA: 279x101x142 (DxWxH) |
1000 – 2000VA: 320x130x182 (DxWxH) | |
3000VA: 460x138x166 (DxWxH) | |
Weight (Kg) | 650VA : 4.3 |
1000VA : 7.9 | |
1500VA : 11 | |
2000VA : 10.7 | |
3000VA : 19.7 |
650VA Vectronic Offline UPS
₦22,000 ₦30,000
Description:
Profile: Compact
Rating: 650VA
Voltage: 220/230Vac
Frequency: 50Hz
In-built AVR: Very Wide Input Range
Related products
-
UPS
Mercury ELITE PRO 1000VA UPS
0 out of 5(0)Mercury ELITE1000 PROELITE1000 PRO
​When it comes to power solutions, you can rest assured when you use Mercury UPS. Mercury offers you a wide range of configurations. No matter you are a home user or you are looking for a corporate solution, you can rely on Mercury UPS.Features:
- Output Short Circuit Protection
- Intelligent Battery Management
- Over Temperature Protection
- Wide Range Of Input Voltage
- Overload Protection
- Auto Restart
- Dataline Protection
- Surge Protection
- DC Start
Specifications:
- Input Voltage 220VAC
- Input Frequency 50Hz
- Input Phase Single Phase
- Input Socket with FUSE
- Cold Start (0~100% load)
- Press the ON / OFF Switch
- Input Range (220V) 140V~285V
- Normal Frequency 50Hz
- Rating Output (VA) 1000VA
- Rating Output (W) 600W
- Waveform Battery Mode (Simulated Sine Wave)AC Mode (Sine Wave)
- Power Factor 0.6
- Rating Voltage 220V
- Output Range 220VAC +17~22%(No Load Connected)
- Rear Output Socket 3x IEC – Battery Backup
- Transfer Time Typical 8ms (max 15ms)
- Short Circuit Protection Line
- Mode FUSE & Software Protection 100%~120% (gives alarm & shut down in 3min)120%~130% (beeps alarm & shut down in 30s)>130% (shut down immediately)
- Battery Mode Software Protection controlled by CPU100%~110% (gives alarm & shut down in 10s)>110% (shut down immediately)
- Battery & Runtime Rating 12V / 9AH x1
- Battery & Runtime Backup Time Typical 8mins~20mins
- Battery & Runtime Change Current 1.5A (max)
- Battery & Runtime Over Charge >14.8V ±0.5 (Stop Charging)
- Battery & Runtime Protection
SKU: n/a -
UPS
APC SMART UPS SRT5KXLI 5000VA 230V
0 out of 5(0)Output
OUTPUT POWER CAPACITY
4500 Watts / 5000 VA
MAX CONFIGURABLE POWER (WATTS)
4500 Watts / 5000 VA
NOMINAL OUTPUT VOLTAGE
230V
OUTPUT VOLTAGE DISTORTION
Less than 2%
OUTPUT FREQUENCY (SYNC TO MAINS)
50/60Hz +/- 3 Hz
OTHER OUTPUT VOLTAGES
220, 240V
CREST FACTOR
3 : 1
Double Conversion Online
WAVEFORM TYPE
Sine wave
OUTPUT CONNECTIONS
(2) IEC Jumpers (Battery Backup) , (4) IEC 320 C19 (Battery Backup) , (6) IEC 320 C13 (Battery Backup)
BYPASS
Internal Bypass (Automatic and Manual)
Input
NOMINAL INPUT VOLTAGE
230V
INPUT FREQUENCY
40 – 70 Hz (auto sensing)
INPUT CONNECTIONS
Hard Wire 3 wire (1PH+N+G)
INPUT VOLTAGE RANGE FOR MAIN OPERATIONS
160 – 275 V
INPUT VOLTAGE ADJUSTABLE RANGE FOR MAINS OPERATION
100 – 275 (half load)V
OTHER INPUT VOLTAGES
220 , 240
Batteries & Runtime
BATTERY TYPE
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
INCLUDED BATTERY MODULES
2
TYPICAL RECHARGE TIME
1.5 hour(s)
REPLACEMENT BATTERY
APCRBC140
RBC QUANTITY
1
NOMINAL BATTERY VOLTAGE
192V
Communications & Management
INTERFACE PORT(S)
RJ-45 10/100 Base-T , RJ-45 Serial , Smart-Slot , USB
AVAILABLE SMARTSLOT™ INTERFACE QUANTITY
1
CONTROL PANEL
Multi-function LCD status and control console
AUDIBLE ALARM
Audible and visible alarms prioritized by severity
EMERGENCY POWER OFF (EPO)
Yes
Surge Protection and Filtering
SURGE ENERGY RATING
480 Joules
Physical
MAXIMUM HEIGHT
432.0 mm
MAXIMUM WIDTH
130.0 mm
MAXIMUM DEPTH
720.0 mm
NET WEIGHT
54.43 kg
SHIPPING WEIGHT
63.6 kg
SHIPPING HEIGHT
330.0 mm
SHIPPING WIDTH
610.0 mm
SHIPPING DEPTH
960.0 mm
COLOR
Black
UNITS PER PALLET
6.0
Environmental
OPERATING ENVIRONMENT
0 – 40 °C
OPERATING RELATIVE HUMIDITY
0 – 95% non-condensing %
OPERATING ELEVATION
0-3000 meters
STORAGE TEMPERATURE
-15 – 45 °C
STORAGE RELATIVE HUMIDITY
0 – 95% non-condensing %
STORAGE ELEVATION
0-15000 meters
AUDIBLE NOISE AT 1 METER FROM SURFACE OF UNIT
55.000 dB
ONLINE THERMAL DISSIPATION
931.000 BTU/hr
PROTECTION CLASS
IP 20
Conformance
APPROVALS
CE , CE Mark , EAC , EN/IEC 62040-1 , EN/IEC 62040-2 , IRAM , RCM , VDE
STANDARD WARRANTY
3 years repair or replace (excluding battery) and 2 years for battery
Sustainable Offer Status
ROHS
Compliant
REACH
REACH: Contains No SVHCsSKU: n/a
Recently Viewed products
30kVA/192V 3 PHASE HDSX SERIES INVERTER
HDSX Inverter
15KVA – 50KVA
The HDSX series Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
3kVA 24v Inverter ISH series
Zektron ISH series is a pure sine wave inverter with fully digital microprocessor control and a wider input voltage, this inverter is compatible with generators. With its transformer design, it can provide more protection to the load which is under unstable power condition
Zektron 6kva Online UPS TS11 Series
Zektron online UPS TS-11 series adopts online double conversion design and digital control technology and it features high input and output power factor (0.9). With ECO mode for energy-saving, intelligent battery management and excellent network management, it is a cost-effective power solution for your critical devices. When UPS is on battery mode, it can shut down unnecessary load and extend the backup time of the critical load.
3KVA 24V pure sine wave inverter
High reliable system
Advanced digital automatic control technology to ensure the power durable and reliable
Strong Environment Adaptability
Full Display Information
LCD Display Mode
Full Display Function
30W All in one solar street light
30w All In One Solar Street Light Outdoor For Smart City Public Lighting