Input | |
Voltage: | 220 / 230 / 240 Vac |
Tolerance | Normal Over-voltage: 280V |
Withstand Over-voltage: 284V (max limit 285V) | |
Under-voltage limit: 145V (lowest limit 142V) | |
Output | |
Voltage: | 220/230V ± 10%, ± 1% on battery |
Power Factor | 0.6 . |
Transfer Time: | 2 – 6 ms (Typical) |
Frequency: | 50Hz (On Battery) |
Waveform: | Sine Wave on normal; Simulated Sine on battery |
DC Bus: | |
650VA | 12V |
1000VA | 24V |
1500VA | 24V |
2000VA | 24V |
3000VA | 48V |
Cold-Start Function: | Yes |
Charging Time: | 6hr to recover to 90% capacity |
Battery Charging in OFF Mode: | Yes |
User Interface: | |
Indications for | Normal mode |
Battery mode / mains fail | |
Low battery | |
UPS fault | |
Environment: | |
Temperature: | 0 ~ 40oC |
Humidity: | 20 ~ 90% Non-condensing |
Noise Level: | Noise Level: Less than 40dB |
Physical: | |
Dimensions | 600 – 650VA: 279x101x142 (DxWxH) |
1000 – 2000VA: 320x130x182 (DxWxH) | |
3000VA: 460x138x166 (DxWxH) | |
Weight (Kg) | 650VA : 4.3 |
1000VA : 7.9 | |
1500VA : 11 | |
2000VA : 10.7 | |
3000VA : 19.7 |
650VA Vectronic Offline UPS
₦22,000 ₦30,000
Description:
Profile: Compact
Rating: 650VA
Voltage: 220/230Vac
Frequency: 50Hz
In-built AVR: Very Wide Input Range
Related products
-
UPS
Tescom 10KVA Transformer Online UPS
0 out of 5(0)- Output Isolation Transformer
- Up to 91% Efficiency
- Static By-pass
- LCD Front Panel
- 64 Events Memory
- RS232 and Relay Contacts
- Custom Input and Output Voltage Range
- SNMP Compatible Communication
- T-MON Remote Monitoring Software
- Parallel Operation
- Manufactured according to EC Directive, 62040
- Input Frequency 50Hz/60Hz (+/-) 5%
- Output Frequency 50Hz
- Sealed Lead Acid – Maintenance Free Batteries
- Frequency Tolerance – Line synchronized: (+/-) 2%, Free Running: (+/-) 0.2%
- Overload Protection – 100% – 125% load: 10 min., 125% – 150% load: 1 min., >150% load: by pass
- Serial Communication: Dry Contacts & RS232
- 5 years spare parts support
- 1 year warranty
SKU: n/a
Recently Viewed products
Pure Sinewave Inverter 1.5kva Solar Hybrid
1, On-line ups, 12v input.
2, Pure sine wave.
3, Solar hybrid charger up to 50A.
4, Inbuilt high efficient charger up to 28A,charging power input range 155v-265v.
5, Automatic cut off when fully charged 3 stages charging to maximize the protection.
6, Fully & intelligently protected (Out put short circuit, over load, in put high or low voltage,lack voltage alarm, anti polar, high temperature, etc)
Note: if you donot have electricity but only have solar panel to charge, you should always keep the switch on for the solar pannel current to come in. In case of cutting all the supply off, you can use the circuit breakers at the back to do so.
A&E 10KVA HYBRID INVERTER
Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.
Built-in MPPT solar charge controller 80A/100A/200A
MPPT efficiency max 98%
Powerful charge rate up to 140Amp
DC start &Automatic Self-Diagnostic Function
WIFI / USB monitoring function with free CD (wi-fi optional)
Supporting AGS, BTS port
Compatible to generator