Input | |
Voltage | 400 Vac |
Tolerance | 320 – 450V |
Frequency | 50Hz ± 6% |
Output | |
Voltage | 400Vac ± 1% |
Power Factor | 0.8 |
Transfer Time | 0 ms |
Frequency | 50Hz ± 6% (On Mains) |
50Hz ± 0.5% (On Battery) | |
Waveform | Pure Sine Wave |
THDi | Linear Load ≤ 3%; Non-linear Load ≤ 5% |
Crest Factor | 3 : 1 (Max) |
Bypass Facility | Maintenance Bypass and Static Bypass |
DC Bus / DC Functions: | |
DC Bus Voltage | 384V |
Charging Current | 5 – 20A, Adjustable |
Cold-Start Function | Yes |
Battery Charging in OFF Mode | Yes |
Battery Type | Sealed, Maintenance-free VRLA |
LCD User Interface: | |
Metering / Indications for | Voltage |
Load % | |
Frequency | |
General Status | |
Alarm | |
Communication: | |
Interfaces | RS232 |
Overload | |
105~125% | 10 mins (Output swithes to bypass after 60s) |
>130% | 1 min |
Environment: | |
Temperature | 0 ~ 40oC |
Humidity | 20 ~ 90% Non-condensing |
Altitude | < 1000m |
IP Class | 20 |
Physical: | |
Dimensions (mm) | 10-20kVA : 560 x 700 x 1040 (W x D x H) |
30-40kVA : 660 x 800 x 1380 (W x D x H) | |
60-80kVA : 1540 x 880 x 1570 (W x D x H) | |
100-200kVA : 2000 x 980 x 1800 (W x D x H) | |
Weight (Kg) | 10kVA : 260kg |
15kVA : 350kg | |
20kVA : 400kg | |
30kVA : 480kg | |
40kVA : 650kg | |
60kVA : 650kg | |
80kVA : 1200kg | |
100kVA : 1330kg | |
120-200kVA : On Request |
3kVA Vectronic Online UPS
₦260,000 ₦310,000
Description:
Profie: Tower
Range: 3kVA
Voltage: 400Vac
Frequency: 50Hz
Related products
-
UPS
APC APRBC 140 UPS Replacement Battery Catridge For Select Smart-UPS
0 out of 5(0)Genuine APC replacement battery cartridges (RBC) are tested and certified for compatibility to restore UPS performance to specification
Includes all required connectors, Battery recycling guide, Installation guide, Reusable packagingSKU: n/a
Recently Viewed products
50kVA/360V 3 PHASE HDSX SERIES INVERTER
HDSX Inverter
15KVA – 50KVA
The HDSX series Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
80A MPPT Solar Charger controller (12V- 48V)

80A MPPT Solar Charger controller (12V- 48V)
12V/24V36/48V Auto work,parallel design
Multi-stage charging optimizes battery performance
MPPT eficiency >99.5%, Peak conversion efficiency 97.5%
Compatible with Gel. AGM.Flooded. Sealed lead acid and Lithium battery
Comprehensive protection
Heatsink cooling, quiet operation
Comfortable installation and commissioning
Monitoring your solar harvest on line via RS485 communition, Ethernet/RS232 communication Optional
40kVA/360V 3 PHASE HDSX SERIES INVERTER
HDSX Inverter
15KVA – 50KVA
The HDSX series Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
100A/384V Kartel solar charge controller (PWM)
Features
Intelligent battery management function, extend battery life
Wide PV input voltage range, convenient for system configuration.
Multiple working modes to adapt different working occasion.
Advanced PWM tracking, 99% tracking efficiency
Submersible DC Solar Water Pump + Inbuilt Controller
Submersible DC solar water pump is designed as DC brush motor driving pump impellers, by connecting to solar panels directly. The power from solar panels can drive this pump. This type of pump is mostly used in areas, where lack of electricity or strict requirement for environmental protection. DC solar pump is suitable to pump and drainage water, which doesn’t need a controller. Moreover, the installation is very simple. This type of pump is mainly used in homes, institutions, fields of power plants, steel mills, mining, chemical, fire, water plants, agricultural irrigation, and other industries. Specifications: Voltage: 24/36volts Power: 250watts Max flow: 2(M3/h) Max head: 25m Outlet: 1” Solar Panel capacity: 250/300watts – (24volt). Battery Capacity: 24volt Free installation Cable: 20m. Higher capacities are available on request.
MAX 48V 10kWH Lithium ion Battery
Application : •All Purpose •Alarm & Security Signal •Uninterruptable Power Supply (UPS) •Electronic apparatus & Equipment •Electrical Power Supply (EPS) •Communication power supply •Emergency Backup Power •DC power supply •Emergency Light •Auto control system
50kVA/360V 3 PHASE HDSX SERIES INVERTER
HDSX Inverter
15KVA – 50KVA
The HDSX series Inverter is packed with powerful features such as pure sine wave output, intelligent LCD integration display and an added fault query function, which makes its operation easy to monitor in real time.
The HDSX Series higher KVA solutions offer high quality and reliable power back-up solutions for running such loads, meeting such needs and handling such equipment
60A/12V/24V Kartel solar charge controller MPPT
Features
Intelligent battery management function, extend battery life
Wide PV input voltage range, convenient for system configuration.
Multiple working modes to adapt different working occasion.
Advanced MPPT tracking, 99% tracking efficiency
1.5kVA/12V NB SERIES INVERTER
NB Series Inverter
1.5kVA
The NB Series inverters are specially designed for industrial, outdoor, and rail applications.
This high-quality range of inverters will suit your needs for stable power in any strained environment, plus will give you the benefit of small units coupled with a great variety of technical features.