Input | |
Voltage | 400 Vac |
Tolerance | 320 – 450V |
Frequency | 50Hz ± 6% |
Output | |
Voltage | 400Vac ± 1% |
Power Factor | 0.8 |
Transfer Time | 0 ms |
Frequency | 50Hz ± 6% (On Mains) |
50Hz ± 0.5% (On Battery) | |
Waveform | Pure Sine Wave |
THDi | Linear Load ≤ 3%; Non-linear Load ≤ 5% |
Crest Factor | 3 : 1 (Max) |
Bypass Facility | Maintenance Bypass and Static Bypass |
DC Bus / DC Functions: | |
DC Bus Voltage | 384V |
Charging Current | 5 – 20A, Adjustable |
Cold-Start Function | Yes |
Battery Charging in OFF Mode | Yes |
Battery Type | Sealed, Maintenance-free VRLA |
LCD User Interface: | |
Metering / Indications for | Voltage |
Load % | |
Frequency | |
General Status | |
Alarm | |
Communication: | |
Interfaces | RS232 |
Overload | |
105~125% | 10 mins (Output swithes to bypass after 60s) |
>130% | 1 min |
Environment: | |
Temperature | 0 ~ 40oC |
Humidity | 20 ~ 90% Non-condensing |
Altitude | < 1000m |
IP Class | 20 |
Physical: | |
Dimensions (mm) | 10-20kVA : 560 x 700 x 1040 (W x D x H) |
30-40kVA : 660 x 800 x 1380 (W x D x H) | |
60-80kVA : 1540 x 880 x 1570 (W x D x H) | |
100-200kVA : 2000 x 980 x 1800 (W x D x H) | |
Weight (Kg) | 10kVA : 260kg |
15kVA : 350kg | |
20kVA : 400kg | |
30kVA : 480kg | |
40kVA : 650kg | |
60kVA : 650kg | |
80kVA : 1200kg | |
100kVA : 1330kg | |
120-200kVA : On Request |
3kVA Vectronic Online UPS
₦260,000 ₦310,000
Description:
Profie: Tower
Range: 3kVA
Voltage: 400Vac
Frequency: 50Hz
Related products
-
UPS
APC Smart UPS 1500VA USB & Serial RM 2U 230V
0 out of 5(0)Protects connected loads from surges, spikes, lightning, and other power disturbances. Automatically starts up the connected equipment upon the return of utility power. Periodic battery self-test ensures early detection of a battery that needs to be replaced. Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR).
SKU: n/a
Recently Viewed products
60A/12V/24V/48V Kartel solar charge controller MPPT
Features
Intelligent battery management function, extend battery life
Wide PV input voltage range, convenient for system configuration.
Multiple working modes to adapt different working occasion.
Advanced MPPT tracking, 99% tracking efficiency
Felicity Solar 750VA 12V Pure sine wave Inverter
Solar inverter, or converter, or PV inverter converts the variable DC output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be off-grid electrical network. It is a critical balance of system–component in a solar power system, allowing the use of ordinary AC-powered equipment.
100A MPPT Solar Charger controller (12V- 48V)

100A MPPT Solar Charger controller (12V- 48V)
12V/24V36/48V Auto work,parallel design
Multi-stage charging optimizes battery performance
MPPT eficiency >99.5%, Peak conversion efficiency 97.5%
Compatible with Gel. AGM.Flooded. Sealed lead acid and Lithium battery
Comprehensive protection
Heatsink cooling, quiet operation
Comfortable installation and commissioning
Monitoring your solar harvest on line via RS485 communition, Ethernet/RS232 communication Optional
SMK 4kva 800V 2 pole DC surge protective device

SMK 4kva 800V 2 pole DC surge protective device
A surge protector contains metal oxide varistor, or MOV, which diverts any extra voltage to ensure devices receive a consistent power level. The MOV works like a pressure-sensitive valve. When the MOV detects high voltage levels, it reduces resistance. If voltage levels are too low, it increases resistance